Tranter heat exchanger manual pdf

Alfa laval phe manual m15, tl10, tl20, ts20, mx25, m30. Tranter service centers have the experience and knowhow to refurbish all brands of plate heat exchangers in our shops or in your facility. The name of kelvion is indeed new, but we are continuing a. By providing the right answers to a broad range of heat transfer needs platecoil heat transfer equipment has been saving. Tranter service heat exchangers en cad pdf catalogs. It is important that bolts are tightened uniformly and in diametrically staggered. You should study this manual thoroughly before operating the unit and follow the instructions with care. A certified technicians are available to disassemble and assemble heat exchangers at your facility. Pressure drop requirements for plate heat exchangers technical article. If exchanger misapplication or maintenance needs are indicated as causes, the tranter team will provide you with an alternate exchanger configuration that will resolve the issue, or a costefficient pm service program to address maintenance issues.

Above these values, an alternate type of heat exchanger would have to be selected. A tranter applications engineer familiar with your process will respond to your query promptly. Heat exchanger heat exchanger engineering thermodynamics. We use your heat exchanger serial number to verify its original design conditionsthe only authorized. Discharge the fluid with water and monitor the situation through the glass tube. Storage procedures when a superchanger plate and frame heat exchanger is to be placed in storage for six months or longer, the procedures listed below must be followed. Plate heat exchanger eng 9 eng manual cleaning opening drain the plate heat exchanger. It is up to you to decide which method is best suited to your operation. Chapter 5 heat exchangers faculty of engineering and. Plate type heat exchangers heat exchanger heat transfer.

At tranter and our authorized service facilities, you get more than genuine tranter oem parts and our renowned customer service. Both reactive or proactive approaches to maintenance have advantages and disadvantages. If the unit has been recently shipped from our factory and is unused, disregard steps 2. Hrs group companies are specialist in heat transfer technology. To avoid hand injuries owing to sharp edges, protective gloves should always be worn when handling plates and protective sheets. Gasketed plate heat exchangers tranter provides the worlds largest range of plate heat exchangers phes for a variety of applications. Plate heat exchanger superchanger tranter pdf catalogs. Propellent keeps over 15,000 plate and gaskets in stock, which makes us have the ability to supply immediate shipment with most requests. Advanced plate heat exchangers spanning a wide product range offer proven performance in broad applications involving liquids, gases, steam and twophase flows. Technical specialists at tranter service centers have the experience and knowhow to repair all brands of plate heat exchangers in our shops or in your facility. Inspect the sliding surfaces of the carrying bar and wipe clean. A 22 x 47 platecoil provides the same heat transfer as 32 ft.

The phes are built on a modulebased concept and are designed to provide maximum efficiency in transferring heat from one liquid to another, or from steam to. Combining each of these resistances in series gives. With a tranter service program you get a grip on things before they become a problem. T ranter brings compact heat transfer solutions to customers across north and south america, backed by local service coverage. In the event your heat transfer require ments are relatively uncomplicated, the infor mation presented in this manual will allow you to specify the platecoil. However, the familiar performance and quality will remain constants. Furthermore, dont touch it until complete cooldown to the normal temperature after the shutdown. Backed by our comprehensive experience and worldwide presence, tranter offers you exceptional system performance.

Tranter is the home of the broadest range of welded heat exchangers in the world. With regular service and maintenance you keep control of your heat exchangers condition so that you can maintain optimum performance. These industrial solutions combine the extensive array of heat exchangers for evaporation, pasteurization and uht, pumps rotary, centrifugal, inducer, etc. Whatever your heat exchanger brand, we are ready to restore them to oem nameplate performance. The heat exchanger is opened in accordance with paragraph to 5.

At the forefront of heat exchanger technology for over 60 years. Maintaining a plate heat exchanger and its related cost is not. Alfa laval 2pass gasketed plateandframe heat exchanger duration. Tranter specializes in solving heat transfer problems in a variety of. The heat exchanger must be isolated from system vibrations using flexible piping connections and isolation pads on the mounting feet. When heat exchanger handles steam and other fluid of high temperature, it has hazard of burns. Consult tranters entire plate heat exchanger superchanger catalogue on directindustry. Fluids normally run countercurrently through the heat exchanger.

Heat exchangers jordan university of science and technology. Tranter phe is a global heat transfer company with representatives around the world. When you are interested in the possibilities of improved operation with tranter heat exchangers, download, complete and return the appropriate application data form below. Maintaining a plate heat exchanger crane engineering. At the forefront of heat exchanger technology for more than 85 years tranter top quality, highperformance, proprietary products are on the job in demanding industrial and commercial installations around the world. Instruction and safety manual plate heat exchangerr r20. The actual limitations for a particular heat exchanger are a function of the materials selected for the gaskets and plates. The phes are built on a modulebased concept and are designed to provide maximum efficiency in transferring heat from one liquid to another, or from steam to liquid.

Alfa laval, apv, apvpasilac, apischmidtbretten, funke, gea, sondex, swep, tranter. Alfa lavals tranter brand intends to consolidate its manufacturing of welded heat exchangers. Tranter product literature provides a wealth of heat exchanger information. Tranter must have serial or drawing number to properly identify your equipment. In contrast to the parallel flow heat exchanger, the counter flow heat exchanger can have the hottest coldfluid temperature greater than the coldest hotfluid temperatue. Each heat exchanger is also delivered with a compact iom manual with written design limitations. The tranter heat exchanger program is ideally suited for ethanol.

Sec technical catalogue all sectionsview download individual sections 1 to 12. Thats why we offer genuine tranter replacement parts and service to every customer. When the heat exchanger is under running or pressurizing, never unscrew any of the tightening bolts. If the heat exchanger is located at the inlet or discharge of a blower with a pulsating flow, such as a roots type rotary lobe blower, the heat exchanger must be protected from the pulsation by a chambered silencer. Heat exchangers a heat exchangers operation manual the heat transfer people. If used as natural draft, they can meet 1535% of process heat duty. The heat transfer area of a gasketed plate heat exchanger consists of a series of corrugated plates, assembled between a frame and pressure plates to retain pressure. Apv offers highly effective turnkey automation and process engineering solutions.

Malfunctions and changes in heat transfer can have severe consequences on operational costs and may affect product quality. Tranter, a global engineering and manufacturing group, brings compact heat transfer solutions to customers worldwide, backed by local service coverage. Weight about 12 as much as equivalent pipe coil na lightweight platecoil units are handled easily by one or two individuals no need for hoisting machinery. Opening and cleaning the heat exchanger is necessary when products crystallise or heavily foul the plates or if the heat transfer surfaces have been scorched. Counter flow heat exchangers are the most efficient of the three types. Sec series model drawings and data sheets view download plplt series modelsview download. Heat exchangers 73 individual thermal resistances of the system. Usa, a corporation of platetype exchanger manufacturing companies, including swep cbe international ab, swep phe and tranter radiator. Uses fans to circulate air around the tubes through which hot fluid flows. We guarantees all plates and gaskets sold with and warrant y p eriods compared to the originals. The 60ad serpentine platecoil pass design is desirable for use with liquid heat transfer media. Its unique design remains the key to both its high heat transfer efficiency and versatility for heating and cooling applications.

The higher internal velocities obtained with liquids in the serpentine design generally improve overall heat. Maintaining a plate heat exchanger by joe bell, tranter, inc. Improve your heat exchanger performance and operations. Plate type heat exchangers free download as powerpoint presentation. Manual for shell and tube heat exchangers headquarters. Pass pure water through the heat exchanger for 510 minutes. Heat exchangers on food duties should be cleaned every day, a suggested method is. Maintaining a plate heat exchanger and its related cost is not just a good idea it is a necessity for any successful business.

Steps for manual cleaning of plates 37 plate cleaning tips 38 cleaninginplace cip 38 back flushing and strainers 39 cleaning guidelines 39 troubleshooting 40. Generally used with cold water, high temperature hot water, hot oil and refrigerants. Gasketed plate heat exchangers tranter pdf catalogs. For phe parts, service or performance ratings, contact one of tranter s authorized service centers see full information for contacting. See more ideas about heat exchanger, plates and locker storage. Alfa laval group a world leader in heat transfer, centrifugal separation and fluid handling has today announced that tranter will initiate structural changes to secure longterm competitiveness for its welded heat exchanger business in europe. However, the term is commonly used to equipment in which two process streams exchange heat with each other. Mounting instructions adequate space should be provided around the heat exchanger for mounting, insulation and maintenance.

1247 401 1418 492 428 1170 1514 1521 1353 1285 692 519 766 1307 92 309 481 111 1344 419 227 610 306 294 1423 904 1440 1380 750 1417 1320 658 957 1022 576 1372 1127 893 1196 127